名媛直播

banner

Knowledge

Home>Knowledge>Content

Diagnosis Case Of Fault Error Code For Excavator Repair

May 06, 2020

When the device is abnormal, sometimes the corresponding code will be displayed in the middle of the lower part of the display, each code has its own specific meaning, thus, you can analyze the cause of the fault according to the information contained in the different codes And parts, at the same time work out corresponding treatment methods. Checking the fault code during machine maintenance is helpful to quickly repair the excavator fault. Entering the excavator monitoring to view the fault code requires a password, please refer to the relevant tutorial.


1301 Engine oil pressure is too low


1302 Engine coolant temperature is too high


1303 Hydraulic oil temperature is too high


1304 Intake air filter clogged


1305 Abnormal battery voltage


2304 Calibration data error


3201 Monitor RAM abnormality


4101 Excessive power supply to controller (43V)


4102 PRV current is too large


4103 PRV open


4104 monitor power supply (digital output) overcurrent


4105 Overcurrent in digital output (ditch solenoid valve)


4106 Overcurrent in digital output (fine control solenoid valve)


4107 Overcurrent in digital output (running speed change solenoid valve)


4108 Overcurrent in digital output (driving alarm)


4109 Spare solenoid 1 (digital output) overcurrent


410A Digital output overcurrent (turntable brake solenoid valve)


410B Spare solenoid 2 (digital output) overcurrent


4201 Engine speed is abnormal


4202 Short circuit of engine coolant temperature sensor connected to machine body ground


4203 Short circuit of hydraulic oil temperature sensor connected to the machine body ground


4204 The pump delivery pressure PWM sensor connected to the machine ground is shorted


4205 Spare PWM sensor 1 connected to body ground is shorted


4206 The backup PWM sensor 2 connected to the body ground is shorted


4207 PWM sensor of pump delivery pressure is open during energization


420A is connected to the body grounding fuel sensor open circuit


420B The fuel sensor connected to the battery voltage is open or shorted


420C power supply is too low (less than 23 volts)


420D power supply is too high (above 32 volts)


420E engine speed knob is not in one of the 10 designated positions


4301 The data of the alternator and the speed sensor do not match 1 (the alternator is abnormal)


4302 The data of the alternator and the speed sensor do not match 2 (the speed sensor is abnormal)


4303 Engine stall


A201 Monitor communication error


The A202 monitor responded to the controller's signal for too long


A203 Communication error in the controller


A20D ADEM communication interrupted