Analysis Of Stick Movement Slower Than Boom Movement Of Kobelco Sk250-10 Excavator

Jun 28, 2022

Fault phenomenon: when a Kobelco sk250-10 excavator carries out light operations such as horizontal extension of the stick, the cooperation between the stick and the boom is not good. The stick is one beat slower than the boom. No abnormality is felt during normal excavation operations.

Troubleshooting detection:

Since the inner diameter of this hose is 5/8, which is a special size, and it is often not sold in hose stores on the street, it is often used when using 1/2 inner diameter Under no-load condition, slightly higher working pressure than usual occurs, and the working sound also sounds as if it is blocked.

Analysis and maintenance:

1. Due to the damage of the cylinder hose, the customer manufactured and installed it at the street hose store Therefore, the inner diameter of the hose is thinner than the standard (cross-sectional area) As a result, the return side is intercepted, resulting in a decrease in speed.

2. Troubleshooting: replace the hose with a regular product.

Knowledge supplement: failure analysis and maintenance of impact energy drop of breaking hammer of sk250-10 excavator of Kobelco

Cause analysis:

1. Insufficient oil, too low air pressure in nitrogen chamber; The pressure of the safety valve is low and the oil temperature is higher than 80 ℃;

2. High return oil back pressure; Deformation of pedal deformation control pipeline; The hydraulic pump is damaged and the oil is polluted;

3. Failure of control valve or related parts: the control valve is stuck; The stroke of control valve is insufficient due to loose bolts; There is an internal failure in the cylinder block, and external substances enter.

Maintenance: check the pipeline and dredge the oil circuit so that the back pressure does not exceed the specified value; Inflate to the specified value; Check and repair the valve and relevant parts or replace them: check the cooling system and reduce the oil temperature to the working temperature; Adjust the pressure of the safety valve to the specified value: check the volumetric efficiency of the oil pump, and replace the oil pump if it is low; Check the filter and hose for insufficient oil absorption; Require the supplier to dismantle and repair; Replace the hydraulic pump; Clean or replace.