(1) Forklift scales used for trade settlement are compulsory verification measuring instruments. After installation, they must pass the verification of the legal measurement verification agency before they can be put into use.

⑵Forklift scales should be used and maintained by full-time operators, familiar with the technical performance, operation methods and use essentials of the forklift scales, and should be able to deal with problems that occur on the site with skill.

⑶Before weighing, check whether the scale body is flexible, clean the scale platform, keep it clean, and check whether there is foreign matter in the scale platform, whether the limit gap is reasonable, whether the wiring is loose and broken, whether the grounding is firm, and the performance of supporting parts Is it good.

⑷The operator should inspect and maintain various components of the forklift scale, regularly check whether the circuit and junction box are dry, and ask a professional to replace it if necessary.

Forklift scale failure analysis and solutions:

Fault 1: Forklift scales are weighed many times, the weight is inconsistent, and there is an error.

Solution 1: Raise the forklift scale to the maximum height, insert a piece of paper into the gap between the scale and the fork cover, and draw a circle to see if there is any place to lean.

Solution 2: Raise the fork cover, loosen the sensor snap ring, adjust it with a large flat screwdriver, and then install the snap ring. If there is no adjusting screw on the sensor, you can loosen the circlip and then remove the fork cover, and then turn down the 4 screws in the cover 2-3 times.

Trouble two: When the forklift scale is weighing, the number of hops does not return to zero

Solution: First, if the problem of inaccurate weighing is found, that is, an item on the scale is the same in both weighing conditions, you need to recalibrate and debug until it is accurate. If the hop count produces a non-zero error, please check whether the sensor fixing screw is loose and is on a plane. If no screw is loose and is on a plane, you need to check whether the sensor itself is defective The four sensors are blocked to see if the linearity is the same). If the sensor itself has a problem, the sensor needs to be replaced.

Trouble three: Forklift scales are unresponsive and often report errors.

Solution: When encountering this problem, first check whether there is a problem with the line, whether there is a short circuit at the end of the wire, whether the wire in the junction box falls off, etc. Secondly, check whether the meter can be turned on normally, and conduct self-check. If the problem is caused by the line, the wiring needs to be connected. If there is a problem with the instrument itself, please contact the manufacturer or the distributor.